Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Arq. bras. oftalmol ; 86(3): 206-209, May 2023. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1439370

ABSTRACT

ABSTRACT Purpose: To evaluate the profile of emergency eye-related visits at a reference eye hospital in Sao Paulo during the first months of the quarantine due to the coronavirus disease (COVID-19) pandemic and to compare it with that in the same period of the previous year. Methods: Data were obtained from the emergency department of Ophthal Hospital Especializado, Sao Paulo, Brazil. All the cases registered between March 23 and May 19, 2020, were included in the study as Group 2020. The cases registered between March 23 and May 19, 2019, were included in the study as Group 2019. Frequency tables were used for the descriptive analyses. The chi-square and Fisher exact tests were applied to compare categorical variables between the groups. Results: We observe a decrease of 46.15% in the number of cases during the COVID-19 pandemic in 2020 compared with the same period in 2019. We observed a significant increase in the incidence rates of the following pathologies in 2020 compared with 2019: eyelid disorders (12.3%), corneal disorders (97.1%), retinal pathologies (173.1%), refraction (62.9%), glaucoma (acute and chronic; 43.9%), scleral alterations (68.8%), trauma (39.3%), herpes (54.7%), and cataracts (549.9%). On the other hand, the incidence rates of the following disorders decreased: conjunctivitis (-33.4%), disorders of lacrimal system (-81.0%), iridocyclitis (-39.9%), and postoperative visits (-80.1%). Conclusion: During the early phase of the COVID-19 pandemic, we observed a drastic decrease in the number of patients who visited the emergency eye service. The main reasons for visiting were also changed, with higher frequencies of high-severity cases such as retina disturbances, cornea disturbances, glaucoma, and trauma and lower frequencies of transmittable conditions such as conjunctivitis.


RESUMO Objetivos: Avaliar o perfil das consultas de emergência oftalmológicas durante os primeiros meses de quarentena por pandemia de covid-19 em um hospital oftalmológico de referência em São Paulo e compará-lo com o mesmo período do ano anterior. Métodos: Os dados foram extraídos do serviço de emergência do Hospital Ophthal Especializado, São Paulo, Brasil. Todos os casos registrados entre 23 de março e 19 de maio de 2020 foram incluídos no estudo como Grupo 2020. Os casos registrados entre 23 de março e 19 de maio de 2019 foram incluídos no estudo como Grupo de 2019. Tabelas de frequência foram utilizadas para análises descritivas. Os testes Qui-quadrado e Exato de Fisher foram aplicados para comparar variáveis categóricas entre os grupos. Resultados: Observamos uma diminuição de 46,15% no número de casos durante a pandemia Covid-19 em 2020 quando comparado ao mesmo período sem pandemia em 2019. Foi observado um aumento significativo nos achados de pálpebra (+12,3%), córnea (+97,1%), retina (+173,1%), refração (+62,9%), glaucoma (+43,9%), esclera (+68,8%), trauma (+39,3%), herpes (+54,7%) e catarata (+549,9%) em 2020 quando comparado para 2019. Por outro lado, houve redução nos casos de conjuntivite (-33,4%), transtornos do aparelho lacrimal (-81,0%), iridociclite (-39,9%) e consultas pós-operatórias (-80,1%). Conclusão: durante a fase inicial da pandemia Covid-19, foi observada uma redução drástica no número de pacientes que procuram o serviço de emergência ocular. Houve também uma mudança nos principais motivos para visitas com frequências mais altas de casos de alta gravidade como distúrbios da retina, distúrbios da córnea, glaucoma e trauma, e frequências mais baixas de condições transmissíveis como conjuntivite.

2.
Arq. bras. oftalmol ; 86(6): e20230073, 2023. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520203

ABSTRACT

ABSTRACT This is a case report involving a 56-year-old male patient with a history of pars plana vitrectomy due to a rhegmatogenous retinal detachment in the right eye that resulted in the implantation of a drainage device after the patient developed secondary glaucoma. Two years after the device's implantation, the patient was referred to our care as his visual acuity had decreased to 20/200 (1.00 LogMAR). At the fundus evaluation, a choroidal amelanotic elevation was observed at the upper temporal equator, and a potential diagnosis was made of amelanotic choroidal melanoma. The ultrasound exam visualized the patient's implanted superotemporal justabulbar drainage device, which revealed a transscleral communication from the plate fibrocapsular's draining space to the suprachoroidal space (fistula). The ultrasound also revealed a focal pocket of choroidal detachment in the patient's superotemporal region, simulating an amelanotic choroidal melanoma. A new pars plana vitrectomy was performed to remove the internal limiting membrane without repercussions at the fistula site. The patient's recovery progressed well, and he regained a visual acuity of 20/70 (0.55 LogMAR). To the best of our knowledge, this is the first case report of this condition.


RESUMO Relato de caso de paciente 56 anos, sexo masculino, com histórico de vitrectomia via pars plana por descolamento de retina em olho direito e posterior implante de dispositivo de drenagem por glaucoma secundário. Dois anos após o procedimento foi encaminhado ao serviço por baixa de acuidade visual (AV) de 20/200 (1.00 LogMAR). À fundoscopia, observou-se uma elevação amelanótica temporal no equador com hipótese diagnóstica de melanoma de coroide amelanótico. O exame de ultrassom mostrou implante de dispositivo de drenagem justabulbar temporal superior com comunicação transescleral para espaço subcoroidal (fístula), sugerindo bolsão focal de descolamento de coroide em equador temporal superior simulando melanoma de coroide amelanótico. O paciente foi abordado cirurgicamente devido membrana epirretiniana com nova vitrectomia via pars plana para peeling de membrana limitante interna, sem repercussões no local da fístula, evoluindo bem com acuidade visual de 20/70 (0.55 LogMAR). Ao nosso conhecimento, este é o primeiro caso relatado nessa condição.

3.
Rev. bras. oftalmol ; 81: e0004, 2022. tab, graf
Article in Portuguese | LILACS | ID: biblio-1357124

ABSTRACT

RESUMO A acurácia do cálculo da lente intraocular não é perfeita, podendo ser comuns erros refrativos pós-operatórios, especialmente em pacientes submetidos à cirurgia refrativa prévia ou na presença de córneas assimétricas. O poder corneano após cirurgia refrativa pode ser medido com maior acurácia utilizando o mapa de poder óptico total na zona central de 4mm, com Orbscan II ou pelo mapa equivalent keratometric reading disponível no pentacam, com medidas centrais de 1,0, 2,0, 3,0 e 4,5mm. O objetivo desta série de casos é demonstrar a abordagem de quatro olhos em condições especiais corneanas, por meio do equivalent keratometric reading do pentacam para mensuração do poder corneano e o utilizando na biometria, em comparação com possíveis resultados obtidos com outras estratégias. Os quatro olhos foram submetidos a procedimentos refrativos prévios, e a lente intraocular escolhida a partir do uso do poder corneano calculado pelo equivalent keratometric reading mostrou excelentes resultados pós-operatórios.


ABSTRACT The accuracy of the intraocular lens calculation is not perfect, and postoperative refractive errors are common, especially in patients who have undergone previous refractive surgery or in presence of asymmetric corneas. Corneal power after refractive surgery can be more accurately measured using the total optical power map in the 4-mm central zone, by means of Orbscan II or equivalent keratometric reading map available on pentacam, with central measurements of 1.0, 2.0, 3.0 and 4.5 mm. The purpose of this case series is to demonstrate four approaches performed in special corneal conditions, using pentacam equivalent keratometric reading to measure corneal power and biometrics, and comparing with possible results obtained with other strategies. The four eyes were submitted to previous refractive procedures, and the intraocular lens chosen from the use of the corneal power calculated by equivalent keratometric reading showed excellent postoperative results.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Biometry/methods , Lens Implantation, Intraocular , Refractive Surgical Procedures , Refraction, Ocular/physiology , Refractive Errors/diagnosis , Refractive Errors/physiopathology , Cataract/diagnosis , Visual Acuity , Corneal Topography , Slit Lamp Microscopy , Lenses, Intraocular
4.
Arq. bras. oftalmol ; 76(6): 341-344, nov.-dez. 2013. tab
Article in Portuguese | LILACS | ID: lil-701283

ABSTRACT

OBJETIVOS: Estudar a habilidade diagnóstica do tomógrafo retiniano de Heidelberg (HRT II), GDx analisador de fibras nervosas (GDx), perimetria azul-amarelo (SWAP), tecnologia de frequência duplicada (FDT) isoladamente e em conjunto no diagnóstico do glaucoma. MÉTODOS: Sessenta glaucomatosos e 60 pacientes normais foram submetidos a exames de HRT II, GDx, SWAP e FDT. HRT foi considerado alterado quando pelo menos uma região do anel neurorretiniano esteve fora dos limites da normalidade, conforme a análise de regressão de Moorfields. GDx alterado foi definido quando pelo menos um índice foi considerado pelo programa do equipamento como fora dos limites normais, excluindo-se o índice simetria, ou ainda quando no gráfico "the deviation from normal graph" apareceu um quadrante com significância abaixo de 5%. O FDT foi considerado anormal quando pelo menos uma região testada apresentou-se com defeito severo ou com a presença de dois defeitos moderados contíguos. Para o SWAP foram adotados os critérios de anormalidade propostos por Anderson. Análise de regressão logística foi realizada. RESULTADOS: Quando foram estudadas as tecnologias isoladamente, a análise de regressão logística apresentou melhores índices de razão das chances para glaucoma com exames positivos para o HRT (22,49), seguido pelo SWAP (21,71). FDT (3,97) e GDx (2,73). Quando se associaram exames positivos de diferentes tecnologias, as razões das chances aumentaram. Nos casos com exames de HRT, FDT e SWAP fora dos limites normais, a razão das chances foi de 252,6 e com HRT, SWAP e GDx alterados, 173,1. Quando associamos exames positivos de diferentes tecnologias, a razão das chances dos pacientes serem glaucomatosos aumentou consideravelmente, chegando a 689,7 com todos os exames fora dos limites normais, o que ocorreu em 26 pacientes deste estudo. CONCLUSÕES: A análise de regressão logística confirmou que a presença de exames alterados de HRT ou SWAP apresentam as maiores razões das chances de glaucoma. A associação de exames alterados aumentou a razão das chances, principalmente, quando o HRT e o SWAP estavam fora dos limites normais.


PURPOSES: In this research was studied the diagnostic ability of the Heidelberg Retinal Tomograph (HRT II), GDx nerve fiber analyzer (GDx), Short-wavelenght Automated Perimetry (SWAP) and Frequency-doubling technology (FDT), all of them together and also separately in the diagnosis of glaucoma. METHODS: Sixty glaucomatous patients and 60 normal ones were submitted to examination with the technology of HRT II, GDx, FDT and SWAP. In the interpretation of HRT, based on the Moorfields regression analysis, were considered abnormal when at least one area of the neuroretinal ring was outside the bounds of normality. GDx was defined as altered, when it was observed that at least one index was considered by equipment program as outside of normal limits, excluding the index symmetry, or when "the deviation from normal graph" appeared a quadrant with significance below 5%. The FDT was considered abnormal when at least one region tested presented with severe defects, or two contiguous moderate defects in at least two reliable tests. For SWAP was adopted the abnormality criteria proposed by Anderson. Logistic regression analysis was performed. RESULTS: When the technologies were studied separately, the Logistic regression analysis showed better odds ratio rates to test positive for glaucoma with HRT (22.49), followed by EAP (21.71), FDT (3.97) and GDx (2.73). When positive tests were associated with different technologies, the odds ratios increased. In cases with HRT, FDT and PAA tests, outside normal bounds, the odds ratio was 252.6. Concerning the HRT, GDx and PAA the result have changed to 173.1. When we associate positive tests from different technologies, the odds ratio of glaucomatous patients have increased considerably, reaching 689.7 with all the tests outside normal bounds, which have happened with 26 patients of this study. CONCLUSIONS: The Logistic Regression analysis confirmed that the abnormal tests of HRT and PAA have shown to be the highest reasons for glaucoma occurrence. The association of abnormal tests increased the odds ratio, especially when the HRT and PAA were out of normal bounds.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Glaucoma/diagnosis , Ophthalmoscopy/methods , Scanning Laser Polarimetry/methods , Visual Field Tests/methods , Case-Control Studies , Intraocular Pressure/physiology , Logistic Models , Optic Disk/pathology , Reference Values , Reproducibility of Results , Sensitivity and Specificity , Visual Acuity/physiology
SELECTION OF CITATIONS
SEARCH DETAIL